UZIN PE 400 is a ready-to-use, solvent-free dispersion moisture barrier for isolating residual moisture in cement-based floors. The product is applied before the floor is smoothed and is suitable for cement and sand-cement screeds above ground level.
When used as a moisture barrier, UZIN PE 400 is applied in two coats. The first coat is diluted 1:1 with water and ensures good anchoring in the substrate. The second coat is applied undiluted and forms the moisture-insulating film.
Under good conditions, both coats can be smoothed approximately three hours after application begins.
Key properties
- Ready to use
- Solvent-free
- Very fast-drying
- Film-forming
- Alkali-resistant
- High vapor impermeability
- Easy to apply with a roller
- Maximum residual moisture content of 4 CM-% on suitable sand-cement screeds
- First coat diluted, second coat undiluted
- Can be smoothed after approximately three hours
- For cement-based floors above ground level
- Suitable for indoor use
- Very low emissions according to EMICODE EC 1 PLUS
Suitable as a moisture barrier
UZIN PE 400 can be applied as a two-coat moisture barrier on:
- Cement-based screeds
- Sand-cement screeds
- Moisture-insensitive cement-based substrates
- New cement screeds with an elevated residual moisture content
- Suitable floors above ground level
- Sand-cement screeds with a maximum residual moisture content of 4 CM-%
After smoothing, suitable as a floor build-up beneath, among others:
- Carpet
- Cork
- Linoleum
- Underfloor-heated floor coverings
- PVC floor coverings
- LVT and PVC design flooring
The floor covering is not bonded directly to UZIN PE 400. After it has fully dried, a suitable smoothing layer must always be applied first.
Also suitable as a bonding primer
UZIN PE 400 can also be used as a bonding primer on cement-based renovation floors with firmly adhering, water-resistant adhesive residues.
For water-resistant adhesive residues on a calcium sulfate or anhydrite floor, a suitable primer must be used, such as UZIN PE 360 PLUS or UZIN PE 375. Do not use UZIN PE 400 here as a moisture barrier.
Not suitable for
UZIN PE 400 is not intended for:
- Floors below ground level
- Basements
- Rising damp
- Floors with standing water
- Calcium sulfate or anhydrite screeds with elevated residual moisture
- Use as a moisture barrier under parquet or wooden floors
- Use as a moisture barrier under rubber floor coverings
- Direct bonding of floor coverings
- Outdoor areas
With higher moisture content, rising damp, or use below ground level, a suitable epoxy or PU moisture barrier is required.
Application on concrete
A different system build-up applies when used on concrete:
- First treat absorbent concrete with UZIN PE 360 PLUS.
- Then apply one undiluted coat of UZIN PE 400.
- For this application, the maximum residual moisture content is 3.5 CM-%.
- Level the floor after it has dried completely.
For concrete, always have it checked whether this system build-up is suitable for the specific situation.
Substrate preparation
The substrate must be load-bearing, dimensionally stable, clean, sufficiently open, and free of cracks and substances that could reduce adhesion.
Remove oil, grease, dust, laitance, and weak or loose layers. Poorly bonded adhesive, smoothing-compound, and floor-covering residues must be removed by sanding, milling, brushing, or dust-free abrasive blasting.
Carefully sand mineral substrates and vacuum them thoroughly. Dense concrete surfaces, such as power-troweled or so-called blue concrete, may need to be shot-blasted.
When used as a moisture barrier:
- The substrate must be dry on the surface
- There must be no standing water
- The surface must be sufficiently absorbent and open
- The moisture content must be determined beforehand using the correct measurement method
- A suitable sand-cement screed may contain a maximum of 4 CM-% residual moisture
Application as a two-coat moisture barrier
Stir UZIN PE 400 thoroughly before use. Use a rectangular application bucket and a fine-foam roller.
First coat
- Mix UZIN PE 400 with clean water in a 1:1 ratio.
- Apply the mixture thinly, evenly, and with complete coverage.
- Avoid thick layers and puddle formation.
- Allow the first coat to dry for approximately one hour under normal conditions.
Second coat
- Apply UZIN PE 400 undiluted.
- Spread the product thinly and evenly with a fine-foam roller.
- Avoid bare spots, thick coats and pooling.
- Allow the second coat to dry for approximately two hours.
- Then apply a suitable UZIN levelling compound.
Do not pour the product directly onto the floor. Clean tools immediately after use with water.
Consumption and drying time
| Coat | Mixing ratio | Consumption of PE 400 | Drying time |
|---|---|---|---|
| First coat | Diluted 1:1 with water | approx. 50–75 g/m² | approx. 1 hour |
| Second coat | Undiluted | approx. 100–125 g/m² | approx. 2 hours |
| Total moisture barrier | Two coats | approx. 150–200 g/m² | approx. 3 hours |
The drying times apply at approximately 20 °C and 65% relative humidity. Low temperatures, high humidity and excessively thick coats slow down drying.
Coverage per canister
When used as a complete two-coat moisture barrier:
| Total consumption | Coverage per 12 kg canister |
|---|---|
| 150 g/m² | approx. 80 m² |
| 175 g/m² | approx. 69 m² |
| 200 g/m² | approx. 60 m² |
The amount of water required for the first coat is not included in this product consumption.
Technical data
- Product type: dispersion moisture barrier
- Packaging: canister
- Contents: 12 kg
- Colour during application: white
- Colour after drying: transparent
- Undiluted consumption: approx. 100–125 g/m²
- Consumption for first diluted coat: approx. 50–75 g/m² of product
- Total product consumption as a moisture barrier: approx. 150–200 g/m²
- Drying time of diluted coat: approx. 1 hour
- Drying time of undiluted coat: approx. 2 hours
- Minimum floor temperature: 10 °C
- Shelf life: at least 12 months
- Application: indoors
- Composition: polymer dispersion, additives and water
Why choose UZIN PE 400?
UZIN PE 400 offers a fast solution for cement-based floors with elevated residual moisture levels. The system is easy to apply with a roller and, under suitable conditions, can be levelled within approximately three hours.
The combination of fast drying, alkali resistance and high vapour density makes it a practical moisture barrier for suitable cement and sand-cement floors above ground level.