{"product_id":"uzin-ke-2000-s-universele-pvc-en-rubberlijm-14-kg","title":"UZIN KE 2000 S Universal PVC and Rubber Adhesive","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eUZIN KE 2000 S universal PVC and rubber adhesive\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eUZIN KE 2000 S is a high-performance, solvent-free dispersion adhesive for bonding PVC, LVT, cushioned vinyl, rubber, linoleum and various types of carpet.\u003c\/p\u003e\n\u003cp\u003eThe adhesive combines a short waiting time with a long open time and can be used for semi-wet, dry and contact bonding. This makes it suitable for a wide range of indoor floor and wall applications.\u003c\/p\u003e\n\u003cp\u003eUZIN KE 2000 S is very easy to spread, heat-reactivatable and resistant to plasticizers. Once dry, the adhesive forms a strong, elastic and durable bond.\u003c\/p\u003e\n\u003ch3\u003eKey properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal PVC and rubber adhesive\u003c\/li\u003e\n\u003cli\u003eSolvent-free dispersion adhesive\u003c\/li\u003e\n\u003cli\u003eVery low emissions\u003c\/li\u003e\n\u003cli\u003eVery easy to spread\u003c\/li\u003e\n\u003cli\u003eShort waiting time\u003c\/li\u003e\n\u003cli\u003eLong open time\u003c\/li\u003e\n\u003cli\u003eHeat-reactivatable\u003c\/li\u003e\n\u003cli\u003eHighly resistant to plasticizers\u003c\/li\u003e\n\u003cli\u003eSuitable for semi-wet bonding\u003c\/li\u003e\n\u003cli\u003eSuitable for dry bonding\u003c\/li\u003e\n\u003cli\u003eSuitable for contact bonding\u003c\/li\u003e\n\u003cli\u003eFor floor and wall applications\u003c\/li\u003e\n\u003cli\u003eSuitable for warm-water underfloor heating\u003c\/li\u003e\n\u003cli\u003eSuitable for castor-wheel loads\u003c\/li\u003e\n\u003cli\u003eFor residential areas, shops and project areas\u003c\/li\u003e\n\u003cli\u003eFor indoor use only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable floor coverings\u003c\/h3\u003e\n\u003cp\u003eUZIN KE 2000 S is suitable for bonding:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHomogeneous PVC floor coverings\u003c\/li\u003e\n\u003cli\u003eHeterogeneous PVC floor coverings\u003c\/li\u003e\n\u003cli\u003eSheet and tile PVC\u003c\/li\u003e\n\u003cli\u003ePVC design flooring and dryback LVT\u003c\/li\u003e\n\u003cli\u003eCushioned vinyl and CV floor coverings\u003c\/li\u003e\n\u003cli\u003eSheet rubber up to 4 mm\u003c\/li\u003e\n\u003cli\u003eRubber with acoustic backing\u003c\/li\u003e\n\u003cli\u003eRubber with foam backing\u003c\/li\u003e\n\u003cli\u003eSheet linoleum up to 3.2 mm\u003c\/li\u003e\n\u003cli\u003eFlexible needlefelt\u003c\/li\u003e\n\u003cli\u003eWoven carpet\u003c\/li\u003e\n\u003cli\u003eCarpet with standard backing constructions\u003c\/li\u003e\n\u003cli\u003eCarpet with latex or foam backing\u003c\/li\u003e\n\u003cli\u003eSuitable insulation and underlays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor special floor coverings, always check the manufacturer's bonding instructions and the current UZIN product data sheet.\u003c\/p\u003e\n\u003ch3\u003eSuitable applications\u003c\/h3\u003e\n\u003cp\u003eThe adhesive can be used on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbent, levelled substrates\u003c\/li\u003e\n\u003cli\u003eCement-based levelling layers\u003c\/li\u003e\n\u003cli\u003eGypsum-based levelling layers\u003c\/li\u003e\n\u003cli\u003eSuitable, level renovation substrates\u003c\/li\u003e\n\u003cli\u003eNon-absorbent substrates suitable for dry or contact bonding\u003c\/li\u003e\n\u003cli\u003eFloors with warm-water underfloor heating\u003c\/li\u003e\n\u003cli\u003eFloors subject to castor-wheel loads\u003c\/li\u003e\n\u003cli\u003eFloors in residential areas\u003c\/li\u003e\n\u003cli\u003eShops and commercial premises\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities and other project areas\u003c\/li\u003e\n\u003cli\u003eInterior walls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSubstrate preparation\u003c\/h3\u003e\n\u003cp\u003eThe substrate must:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBe load-bearing and dimensionally stable\u003c\/li\u003e\n\u003cli\u003eBe sufficiently dry\u003c\/li\u003e\n\u003cli\u003eBe clean and dust-free\u003c\/li\u003e\n\u003cli\u003eBe flat and free of cracks\u003c\/li\u003e\n\u003cli\u003eBe free from oil, grease, wax and other substances that impair adhesion\u003c\/li\u003e\n\u003cli\u003eBe uniformly absorbent for wet or semi-wet bonding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRemove loose layers, weak levelling-compound residues and poorly adhering adhesive residues. Sand the substrate if necessary, then vacuum it thoroughly.\u003c\/p\u003e\n\u003cp\u003eUse a suitable UZIN primer and levelling compound to create a flat, smooth and uniformly absorbent substrate.\u003c\/p\u003e\n\u003cp\u003eNon-absorbent and moisture-sensitive substrates generally need to be levelled to a minimum thickness of 2 mm before standard flooring installation work. Always follow UZIN's system build-up recommendations.\u003c\/p\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAllow the adhesive to reach room temperature before application.\u003c\/li\u003e\n\u003cli\u003eStir the adhesive thoroughly.\u003c\/li\u003e\n\u003cli\u003eApply the adhesive evenly with the notched trowel specified for the floor covering.\u003c\/li\u003e\n\u003cli\u003eDo not apply more adhesive than can be worked within the available working time.\u003c\/li\u003e\n\u003cli\u003eObserve the required waiting time. This depends on the substrate, trowel notch, temperature, humidity and floor covering.\u003c\/li\u003e\n\u003cli\u003ePlace the floor covering in the adhesive bed and carefully rub or roll it down.\u003c\/li\u003e\n\u003cli\u003eEnsure that the adhesive ridges are completely flattened and avoid air entrapment.\u003c\/li\u003e\n\u003cli\u003eRe-roll the surface after approximately 20 minutes.\u003c\/li\u003e\n\u003cli\u003ePay particular attention to seams, end edges and raised edges.\u003c\/li\u003e\n\u003cli\u003eRemove fresh adhesive residue immediately with water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe exact trowel notch and bonding method must be matched to the floor covering. Always follow the floor covering manufacturer's instructions.\u003c\/p\u003e\n\u003ch3\u003eApplication times\u003c\/h3\u003e\n\u003cp\u003eAt approximately 20 °C and 65% relative humidity:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProperty\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTime\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash-off time\u003c\/td\u003e\n\u003ctd\u003eapprox. 10–45 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking time\u003c\/td\u003e\n\u003ctd\u003eapprox. 15–120 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanically loadable\u003c\/td\u003e\n\u003ctd\u003eafter approx. 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeam welding\u003c\/td\u003e\n\u003ctd\u003eafter approx. 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal strength\u003c\/td\u003e\n\u003ctd\u003eafter approx. 3 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe times depend on the amount of adhesive used, the type of floor covering, the absorbency of the substrate and the conditions in the room.\u003c\/p\u003e\n\u003ch3\u003eCoverage\u003c\/h3\u003e\n\u003cp\u003eThe official coverage is approximately \u003cstrong\u003e180–380 g\/m²\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eCoverage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eYield per 14 kg bucket\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e180 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 77.8 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 63.6 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 56.0 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 46.7 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e320 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 43.8 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e380 g\/m²\u003c\/td\u003e\n\u003ctd\u003eapprox. 36.8 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eActual coverage is determined by the trowel notch used, the backing of the floor covering and the structure of the substrate.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct type: universal dispersion adhesive\u003c\/li\u003e\n\u003cli\u003ePackaging: plastic bucket\u003c\/li\u003e\n\u003cli\u003eContents: 14 kg\u003c\/li\u003e\n\u003cli\u003eColour during application: creamy white\u003c\/li\u003e\n\u003cli\u003eColour after drying: transparent\u003c\/li\u003e\n\u003cli\u003eCoverage: approximately 180–380 g\/m²\u003c\/li\u003e\n\u003cli\u003eFlash-off time: approximately 10–45 minutes\u003c\/li\u003e\n\u003cli\u003eWorking time: approximately 15–120 minutes\u003c\/li\u003e\n\u003cli\u003eMinimum floor temperature: 15 °C\u003c\/li\u003e\n\u003cli\u003eMechanically loadable: after approximately 24 hours\u003c\/li\u003e\n\u003cli\u003eSeam welding: after approximately 24 hours\u003c\/li\u003e\n\u003cli\u003eFinal strength: after approximately 3 days\u003c\/li\u003e\n\u003cli\u003eShelf life: at least 12 months\u003c\/li\u003e\n\u003cli\u003eArticle number: 6770\u003c\/li\u003e\n\u003cli\u003ePallet contents: 33 buckets\u003c\/li\u003e\n\u003cli\u003eApplication: floor and wall, indoors\u003c\/li\u003e\n\u003cli\u003eEmission classification: EMICODE EC 1 PLUS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComposition\u003c\/h3\u003e\n\u003cp\u003ePolymer dispersion, modified resins, preservatives, mineral fillers, additives and water.\u003c\/p\u003e\n\u003ch3\u003eWhy choose UZIN KE 2000 S?\u003c\/h3\u003e\n\u003cp\u003eUZIN KE 2000 S is a versatile adhesive for PVC, dryback LVT, rubber, linoleum and carpet. The short waiting time and long working time provide sufficient flexibility during installation, while the adhesive forms a strong and elastic bond after curing.\u003c\/p\u003e\n\u003cp\u003eBecause the adhesive is suitable for wet, semi-wet, dry and contact bonding, one product can be used for various floor and wall applications.\u003c\/p\u003e","brand":"Uzin","offers":[{"title":"6 KG","offer_id":63329606336842,"sku":null,"price":94.95,"currency_code":"EUR","in_stock":true},{"title":"12 KG","offer_id":63329606369610,"sku":null,"price":192.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/2194\/4394\/files\/uzinke2000s.jpg?v=1787655175","url":"https:\/\/portofaltea.es\/pl\/products\/uzin-ke-2000-s-universele-pvc-en-rubberlijm-14-kg","provider":"Port of Altea","version":"1.0","type":"link"}